Detail KRAUTKRAMER DM 5E Digital Ultrasonic Thickness Gauge, Hp: 081380328072, Email : K00011100@ Yahoo.com
Specifications:
Operating Principle : Ultrasonic pulse-echo method
Measurement Modes : Depends on Probe and Material, 0.60 mm to 508 mm ( 0.025” to 20.00” ) in IP to 1st BW Measurement Mode, 2.00 mm to 127.0 mm
( 0.079” to 5.00” ) in Dual-Multi Measurement Mode, the Coating Thickness Range Shall be 0.3 mm to 2.50 mm ( 0” to 0.098” ) .
Measuring Resolution : 0.01 mm Default - Selectable 0.01, 0.1 mm ( 0.001” Default - Selectable 0.001, 0.01” )
Material Velocity Range : 0.508 to 18.699 mm/ msec ( 0.0200 to 0.7362” / msec)
Material Velocity Resolution : 1 m/ s ( 0.0001” / msec)
Units : Inch or Millimeter
Calibration : One-Point Cal, On-Block and Off-Block, Two-Point Cal
Pulser : Excitation Pulse: Spike Pulser
Voltage : 120 V into 50 ohm Load, Using 20 MHz Oscilloscope
Receiver : Bandwidth 500KHz to 12 MHz @ -3 dB
Gain Automatic Gain Control
Display Type : High-Resolution Graphical LCD, 64 x 128 Pixels, 53.0 mm x 27.0 mm with Backlight and Adjustable Contrast
Update Rate : 4 Hz or 8 Hz, User Selectable, 24 Hz Scan Mode Capture Rate
Thickness Value Display : NORMAL View Mode 5 Digit, 10.6 mm ( 0.4” ) High
B-SCAN View Mode 5 Digit, 2.55 mm ( 0.1” ) High
Display of Last Reading : Solid Filled or Hollow Digits Indicate Coupled or Uncoupled Condition
Setups : 9 Standard Setups for Probes
Alarm Settings : Minimum and Maximum Alarms, Range of 0.25 mm to 508 mm, 0. ( 0.010” to 20.00” )
Reading Alternates Between Solid and Hollow When Alarms Are Enabled and Violated
Power Requirements : 2 “ AA” Size Batteries
Battery Life/ Operating Time : Approximately 60 Hours
Instrument Shut-0ff : Selectable ALWAYS ON or AUTO OFF After 5, 10, 15, 30 Minutes of Inactivity
Language : Selectable English, German, French, Spanish, Italian, Russian, Japanese and Chinese
I/ O Connectors : Transducer Dual Lemo 00 ( coax)
Mini-USB Mini-USB to PC
Temperature : Operating -10° C to + 50° C ( + 10° F to + 120° F)
Storage -20° C to + 60° C ( -10° F to + 140° F)
Weight : 223 g ( 0.597 lb) Including Batteries
Size : 138 mm x 32 mm x 75 mm
Shock : IEC 68-2-27 Ea, as per Mil Std 810C Method 516.2 Procedure I with a 15g 11ms Impulse Half Sinusoidal Wave Applied 6 Times per Axis
Sealing : IEC529 / IP54, Dust Proof/ Dripping Water Proof as per IEC 529 Specifications for IP54 Classification
Prices:
DM5E Basic : USD 4, 700.00
( including DA301 Probe and DA231 Cable)
DM5E ( Through Coating) : USD 5, 330.00
( including DA301 Probe and DA231 Cable)
Contact Us :
Mitra Guna Instruments
Up. Pak Harry
Ruko Taman Yasmin Sektor VI
Jl. Ring Road Utara No.134
Bogor 16113
Telp : 021-37699537, 0251-7543316
Hp : 081380328072, 081281161411
Fax : 0251-7543281