Back to Top

Hi, Guest!

BAGIKAN :   

Bagikan :
  • YSI 556 Multi-Probe System, Hp: 081380328072, Email : k00011100@ yahoo.com

YSI 556 Multi-Probe System, Hp: 081380328072, Email : k00011100@ yahoo.com

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
4 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail YSI 556 Multi-Probe System, Hp: 081380328072, Email : K00011100@ Yahoo.com

The YSI 556 simultaneously measures dissolved oxygen, pH, conductivity, temperature, and ORP. Rugged, reliable and waterproof, the YSI 556 MPS ( Multi-Probe System) combines the versatility of an easy-to-use, easy-to-read handheld unit with all the functionality of a multi-parameter system. Featuring an IP-67, impact-resistant case, the YSI 556 MPS assists the user in conforming to GLP standards. Measurements are easy with field-replaceable DO electrode modules and easy-to-use, screw-on cap DO membranes. Two models are available. The standard model measures dissolved oxygen, pH, conductivity, temperature and ORP. The YSI 556 model with an internal barometer provides barometric pressure measurements in addition to the measurements taken by the standard model. Features: * Field-replaceable DO electrode modules * RS232 and compatible with Ecowatch™ for Windows™ data analysis software * Easy-to-use, screw-on cap DO membranes * 3-year warranty on the instrument, 1-year on the probe module and cables * Stores over 49, 000 data sets, time and date stamped * User upgradeable software from YSI * Meets IP-68 water tightness requirements, submersible to 3 feet Order the instrument, cable and accessories separately. Measurement Specifications: Dissolved Oxygen - Range: 0 to 500% air saturation/ 0 to 50 mg/ L. Accuracy: 0 to 200% air saturation, ± 2% of the reading or 2% air saturation, whichever is greater; 200 to 500% air saturation, ± 6% of the reading/ 0 to 20 mg/ L, ± 2% of the reading or 0.2 mg/ L, whichever is greater; 20 to 50 mg/ L, ± 6% of the reading. Resolution: 0.1% air saturation/ 0.01 mg/ L. pH-Range: 0 to 14. Accuracy: ± 0.5% of reading + 0.001 mS/ cm. Resolution: 0.001 mS/ cm to 0.1 mS/ cm ( range-dependent) . Temperature-Range: -5° C to 45° C. Accuracy: ± 0.15° C. Resolution: 0.1° C. ORP-Range: -999 to + 999 mV. Accuracy: ± 20 mV. Resolution: 0.1 mV. Barometer ( optional) - Range: 500 to 800 mm Hg. Accuracy: ± 3 mm Hg within ± 15° C temperature range from calibration point. Resolution: 0.1 mm Hg. Contact Us : Mitra Guna Instrument Lindeteves Trade Centre, Lt GF1 Blok A2 No.37 Jl. Hayam Wuruk 127 Glodok Jakarta Telp : 021-37699537 Hp : 081380328072 Fax : 021-62320340
Tampilkan Lebih Banyak