Back to Top

Hi, Guest!

BAGIKAN :   

Bagikan :
  • SMS125 Smart pH / ORP Controller - Milwaukee, Hp: 081380328072, Email : k00011100@ yahoo.com

SMS125 Smart pH / ORP Controller - Milwaukee, Hp: 081380328072, Email : k00011100@ yahoo.com

Update Terakhir
:
01 / 12 / 2019
Min. Pembelian
:
1 Unit
Dilihat Sebanyak
:
5 kali

Harga

CALL
Bagikan
:

Perhatian !

Perusahaan ini terdaftar sebagai Free Member. Hindari melakukan pembayaran sebelum bertemu penjual atau melihat barang secara langsung. COD (Cash On Delivery) atau bertemu langsung dengan penjual merupakan metode transaksi aman yang kami sarankan.

Detail SMS125 Smart PH / ORP Controller - Milwaukee, Hp: 081380328072, Email : K00011100@ Yahoo.com

With Milwaukee' s Smart controllers you can monitor and control pH and/ or ORP levels directly in your aquarium. All our controllers work with a 12 VDC adapter and can be hanged above your aquarium. The meters have a user selectable set point and a visual LED alarm that is active when the reading is higher ( for pH) or lower ( for mV) than the set point. Also the instruments are supplied with a power plug for CO2 or ozone dosing. With each Milwaukee Smart controller your aquarium will have the individual attention that it needs. " Monitor & control pH & ORP levels with 1 single unit. Dual set points, for pH( 5.5 to 9.5) and for ORP ( 0 to 600 mV) , adjustable with knobs. Simply attach 1 solenoid valves and pump to the plug socket supplied to dose CO2 and ozone as required. The SMS125 has a Visual Led alarms." Specifications : - Range : 0.00 to 14.00 pH; ± 1000 mV ( ORP) - Resolution : 0.01 pH; 1 mV ( ORP) - Accuracy : ± 0.2 pH; ± 5 mV ( ORP) - pH set point : 4 to 8 pH - ORP set point : -200 to 600 mV - pH Alarm : active when measurement is higher than the set points - ORP Alarm active when measurements are lower than set points - pH Output Power Socket : active when measurement is higher than set point - ORP Output Power Socket : active when the measurement is lower than set point - pH Electrode : MA911B/ 2 ( included) - ORP Electrode : MA921B/ 2 ( included) - Environment : 0 to 50° C / 32 to 122° F; max RH 95% - Power Supply : 12 VDC power adapter ( included) - Power Drivers : 115VAC, 2A, 60Hz or 230VAC, 1A, 50Hz - Dimensions : 145 x 80 x 40 mm - Weight : 220 g ( meter only) Accessories: MA911B/ 1 Double junction, gel filled pH electrode with 1 m cable MA921B/ 2 ORP Electrode with BNC connector and 2 m cable M10004B pH 4.01 buffer solution 20 mL sachet ( 25 pcs) M10007B pH 7.01 buffer solution 20 mL sachet ( 25 pcs) M10010B pH 10.01 buffer solution 20 mL sachet ( 25 pcs) MA9015 Electrode storage solution 20 mL sachet ( 25 pcs) M10000B Electrode rinse solution 20 mL sachet ( 25 pcs) MA955 Solenoid valve with 1.5 m cable Ordering Information : SMS125 is supplied complete with 12 VDC adapter, power plug socket for ozone dosing, MA911B/ 2 pH electrode, MA921B/ 2 ORP electrode, 20 mL pH7.01 sachet of calibration solution, calibration screwdriver and instructions. Contact Us : Mitra Guna Instruments Up. Pak Harry Ruko Taman Yasmin Sektor VI Jl. Ring Road Utara No.134 Bogor 16113 Telp : 021-37699537, 0251-7543316 Hp : 081380328072 Fax : 0251-7543281
Tampilkan Lebih Banyak